This analog fuel level indicator is a panel instrument for displaying the fuel level in a tank. The instrument features a black dial, a black bezel, and an analog scale from empty to full.
The indicator can be used with resistive tank senders with either a 240–33 Ω or 0–190 Ω signal. The correct signal input is selected according to the installed sender: black sensor wire for 0–190 Ω and yellow sensor wire for 240–33 Ω. Always follow the labeling on the back of the instrument and the provided wiring diagram.
The instrument is designed for 12/24 V and has red backlighting. When installing in a 24 V system, the voltage-reducing resistors must be used as shown in the wiring diagram. The diagram specifies 150 Ω and 2 kΩ resistors for the 24 V circuit.
The front measures Ø57 mm, while the nominal panel cutout is Ø51 mm. The installation instructions specify a practical cutout dimension of Ø52 mm, a panel thickness of 0.5–20 mm, and at least 55 mm of clear space behind the panel. The instrument depth itself is 45 mm.
The instrument is inserted through the panel from the front and secured from the back with a fastening ring. The position of the instrument housing's alignment tab must be marked before tightening, and the wiring harness is connected to the port on the back.
Key featuresAnalog display of fuel level from empty to full
Selectable sender signal: 240–33 Ω or 0–190 Ω
12/24 V supply
Red backlighting
Black dial and black bezel
Front diameter: Ø57 mm
Nominal panel hole: Ø51 mm
Instrument depth: 45 mm
Panel mounting with fastening ring