A VDO capacitive level sensor for freshwater tanks is designed for the continuous measurement of levels in fresh and drinking water tanks with a depth of 600–1200 mm. The sensor has a maximum length of 1200 mm and can be shortened to fit the specific tank.
The capacitive measuring principle detects the level continuously from empty to full. The sensor uses a 4–20 mA analog output signal and is designed for nominal 12/24 V DC systems. Connection is via two 6.3 mm flat plug terminals on the top of the sensor. This freshwater variant has no separate alarm output.
The sensor rods must only be shortened from the top end. After shortening, the retaining clip must be positioned in the middle of the new sensor height. The rods must not be disassembled and reassembled after shortening, as the seals may be damaged. Furthermore, the enameled surface of the coated sensor rod must be protected against scratches and other damage.
Installation is carried out from the top of the tank through an Ø59 mm mounting hole. The sensor has a 5-hole flange with a 54 mm bolt circle and is mounted with sealing rings. The soft rubber seal is placed under the sensor, and the markings on the sealing rings must be aligned. When installing in a metal tank, the black wire with ring terminal must be used for grounding. The sensor must not be used in aluminum tanks.
The sensor rods are made of SUS 201 stainless steel, and the operating temperature is −30 °C to +70 °C. Calibration is performed with the tank completely full by adjusting the sensor's potentiometer until the connected instrument just reaches the upper limit of the scale. The empty limit requires no separate calibration.
The sensor is compatible with the water level instrument, item no. 27.574.02 in the OCEAN series, as well as ViewLine 52 mm freshwater instruments with capacitive sensor input, Veratron EngineBox, OceanLink TFT, and VMH 70. It must be connected to an instrument or interface that accepts a capacitive 4–20 mA signal. A separate NavBox can convert the signal to NMEA 2000 PGN 127505, but the sensor is not an NMEA 2000 sensor in itself. Sealing kit N05-001-370 is documented for the sensor family.
Key featuresCapacitive, continuous level measurement for freshwater
For tank depths of 600–1200 mm
Maximum sensor length of 1200 mm
Can be shortened to the tank depth
Nominal 12/24 V DC system
4–20 mA analog output signal
Top mounting with 5-hole flange
Ø59 mm mounting hole and 54 mm bolt circle
Operating temperature from −30 °C to +70 °C
Manufacturer number N02-240-404