This vertical stainless steel 316 tank level sender with S5 5-hole flange has a length of 90 cm and is intended for level monitoring in fuel or water tanks. The sender uses a resistance range of 240–33 Ω and can be used in both 12 V and 24 V systems.
A float moves axially along the sensor tube, changing the electrical resistance in line with the liquid level. The signal is read by a compatible 240–33 Ω tank instrument. The sender can be used with relevant instruments from, among others, Teleflex, Aqua Meter, Vetus, S. Giorgio Sein/Veglia, Beede, Medallion, Datcom and Wema, as well as level indicator item no. 27.160.00.
The sensor is made of AISI 316 stainless steel and has an NBR gasket. The product length is 900 mm with a stated tolerance of ±5 mm, while the S5 flange has a diameter of Ø69 mm and five mounting holes. The wire length is 0.46 ± 0.02 m.
The S5 flange is intended for tanks prepared for an international 5-hole flange. When mounting, the gasket must be oriented correctly in relation to the wire direction, and the mounting screws should be tightened gradually in a cross or star pattern. Check that the tank has sufficient depth and clearance for the sender's insertion length of 90 cm.
The sender is rated IP65 and has a documented operating temperature range from −40 °C to +85 °C. The nominal power is 0.125 W, the specified operating current is 0.3 A, and the output resistance tolerance is ±(R × 1.5% + 1 Ω).
The product family is covered by the EMC Directive 2014/30/EU and the RoHS Directive (EU) 2015/863, which amends 2011/65/EU. Associated standard references include EN 61326-1:2013, EN 61000-6:2007, EN 61000-6:2007/A1:2011/AC:2012 and ISO 2768C.
Key featuresFor fuel and water tanks
Resistance range: 240–33 Ω
Universal for 12/24 V
Sensor length: 90 cm
S5 flange with five mounting holes
Flange diameter: Ø69 mm
AISI 316 stainless steel
IP65 and operating temperature from −40 °C to +85 °C
Compatible with 240–33 Ω tank instruments