This vertical tank level sensor in AISI 316 stainless steel with an S5 5-hole flange has a nominal length of 40 cm and is intended for measuring liquid levels in both fuel and water tanks. The float-based sensor is mounted vertically through the top of the tank and is compatible with 12/24 V electrical systems.
The sensor provides an analog resistance signal of 240–33 Ω, corresponding to 240 Ω when the tank is empty and 33 Ω when full. It must be connected to a level gauge designed for the same resistance curve. The sensor has two wires, blue and black, and the sensor connection itself has no polarity requirements. The sensor must not be connected directly to the battery.
The design consists of a Ø12.7 mm sensor tube and an S5 flange with an outer diameter of 69 mm. The flange features five Ø5.5 mm mounting holes on a bolt circle of 54 ±0.25 mm and a plate thickness of 3 mm. An NBR gasket and five M5 screws are included in the documented mounting assembly.
During installation, the sensor length must match the internal depth of the tank so that the float can move freely. The gasket is placed between the flange and the top of the tank, after which the flange is secured with the five screws. The battery must be disconnected and the tank must be empty during installation.
The resistance signal can be used with compatible 240–33 Ω instruments and systems from manufacturers such as Teleflex, Aqua Meter, Vetus, S. Giorgio Sein/Veglia, Beede, Medallion, Datcon, and Wema/Wena. The sensor is also documented for media such as gasoline, diesel, water, wastewater, and alcohol. Always check the instrument's signal range before connection; instruments for 0–190 Ω or 10–180 Ω are not compatible with this signal standard.
The sensor has an IP65 protection rating and a documented temperature range from −40 °C to +85 °C. The nominal electrical power is 125 mW, and the maximum operating current is 300 mA. The construction follows the reference requirement QC/T 413-2002 and is in compliance with the RoHS directive (EU) 2015/863.
Key featuresVertical, float-based tank level sensor
Nominal sensor length: 40 cm
Analog signal: 240–33 Ω
For fuel and water tanks
Compatible with 12/24 V systems
S5 flange with five mounting holes
AISI 316 stainless steel
NBR gasket and five M5 screws
IP65 and −40 °C to +85 °C
RoHS compliance