Vertical tank level sensor in AISI 316 stainless steel with S5 5-hole flange for level measurement in fuel and water tanks. This S5-E variant has a sensor length of 120 cm and provides a 0-190 Ω resistive signal.
The sensor is mounted vertically from the top of the tank. A movable float follows the liquid level along the sensor tube and changes the resistance to the connected instrument. It can be used in 12 V and 24 V installations and is compatible with 0-190 Ω instruments from Yazaki with three wires, Faria Europa, VDO, Uflex, and Guardian.
The sensor tube is made of AISI 316 stainless steel and has an outer diameter of 12.7 mm. The S5 flange measures Ø69 mm, has a thickness of 3 mm, and five mounting holes of Ø5.5 mm located on a bolt circle of Ø54 ±0.25 mm. The gasket is made of NBR/nitrile rubber.
When installing in a tank without an existing flange, use the gasket as a drilling template. The mounting instructions specify a center hole of 40 mm and five screw holes of 4.0-4.2 mm. The sensor and gasket must be oriented identically, after which the five M5 screws are tightened in a star pattern. The uneven S5 hole pattern must be followed; the holes are not placed at five equal angular intervals.
Electrical connection is made with two wires via a 460 ±20 mm cable. The nominal power is 125 mW, and the maximum operating current is 300 mA. The sensor has an IP65 rating and an operating temperature range from −40 °C to +85 °C.
The sensor can also be connected directly to the configurable tank inputs on the Victron Cerbo GX and Ekrano GX when the input is set to the relevant resistance range. It is not intended for direct connection via GX Tank 140. The movable float must always be able to move freely, and the tank depth as well as the permitted sensor length must be checked before mounting.
The product family complies with EMC Directive 2014/30/EU and standards EN 61326-1:2013, EN 61000-6:2007, as well as EN 61000-6:2007/A1:2011/AC:2012. The variant is also covered by RoHS Directive (EU) 2015/863.
Key featuresFor fuel and water tanks
Sensor length: 120 cm
Resistance signal: 0-190 Ω
Universal for 12/24 V
S5 flange with five mounting holes
AISI 316 stainless steel
Flange diameter: Ø69 mm
Sensor tube: Ø12.7 mm
Cable length: 460 ±20 mm
IP65 and −40 °C to +85 °C