This vertical tank level sensor is an analog float sensor for measuring liquid levels in fuel or water tanks. This variant has a nominal sensor length of 120 cm and provides a 240–33 Ω resistance signal to a compatible tank gauge.
The sensor is made of 316 stainless steel and is mounted vertically from the top of the tank. The S5 flange has a standardized 5-hole pattern for tanks prepared for S5/VDO-type flanges. The flange head has an outer diameter of 69 mm, and the gasket is made of NBR nitrile rubber.
The resistance decreases from approximately 240 Ω at empty tank to approximately 33 Ω at full tank. The sensor is designed for 12/24 V systems and can be used with 240–33 Ω gauges from, among others, Teleflex, Aqua Meter, Vetus, S. Giorgio Sein/Veglia, Beede, Medallion, Datcom, and Taiwan/Wena models. The gauge's resistance standard must be checked before installation.
The rated power is 125 mW, and the connected cable length is 0.46 ± 0.02 m. The sensor has an IP65 rating and a specified operating temperature range from −40 °C to +85 °C. The resistance tolerance is ±(R × 1.5% + 1 Ω), while the length tolerance is ±5 mm.
The sensor family is covered by the EMC Directive 2014/30/EU and the specified EN standards. The current variant is also covered by the RoHS Directive (EU) 2015/863 amending 2011/65/EU. The sensor length of 120 cm must match the specific depth of the tank, and a 0–190 Ω sensor cannot be used as a direct electrical replacement without checking the gauge.
Key featuresAnalog vertical float sensor for tank measurement
For fuel, fresh water, and wastewater
Output resistance: 240–33 Ω
System compatibility: 12/24 V
Sensor length: 120 cm
316 stainless steel
S5 5-hole flange with 69 mm outer diameter
IP65 and operating temperature from −40 °C to +85 °C
Cable length: 0.46 ± 0.02 m
NBR gasket