This vertical tank level sensor with S5 flange is a 36 cm long, analog float sensor for measuring levels in fuel and water tanks. The sensor outputs a resistance signal of 240–33 Ω and can be used in 12 or 24 V electrical installations.
The level measurement is performed using a movable, ring-shaped float around the vertical sensor tube. The construction is made of 316 stainless steel and is intended for contact with, among other things, gasoline, diesel, water, alcohol, and wastewater. The sensor has IP65 protection and a documented operating temperature range from −40 °C to +85 °C.
The nominal length of the sensor is 360 mm with a tolerance of ±2 mm. The sensor tube has an outer diameter of 12.7 mm, while the S5 flange measures 69 mm in outer diameter. The flange has five asymmetrically placed mounting holes on a hole circle of 54 ±0.25 mm. The electrical connection is made via two leads with a cable length of 460 ±20 mm.
When installing in a tank without a pre-prepared S5 flange, a center opening of 40 mm and five drill holes of 4.0–4.2 mm must be established. The sensor is lowered vertically through the opening and secured with five M5 screws. An NBR gasket is placed between the tank and the flange to seal the connection.
The nominal power is 125 mW, and the maximum operating current is 300 mA. The function of the sensor can be checked with a multimeter across the two leads while moving the float between the end positions. The tolerance of the resistance output is ±(1 + R × 1.5%) Ω.
The resistance signal is compatible with relevant 240–33 Ω instruments from, among others, Teleflex, Aqua Meter, Vetus, S. Giorgio Sein/Veglia, Beede, Medallion, and Datcom, as well as instrument 27.160.00. The sensor family meets RoHS and EMC requirements and has been tested according to the specified EN standards.
Key featuresVertical, float-based level measurement
For fuel and water tanks
Resistance signal: 240–33 Ω
Voltage: 12/24 V
Sensor length: 36 cm
316 stainless steel
S5 flange with five-hole mounting
IP65 protection
Operating temperature: −40 °C to +85 °C
Cable length: 460 ±20 mm