This vertical 316 stainless steel tank level sensor with S5 flange has a nominal length of 65 cm and a resistance signal of 240–33 Ω. The sensor measures the liquid level using a float that moves along the vertical sensor tube, and it is intended for fuel and water tanks in 12 V and 24 V installations.
The sensor can be used with petrol, diesel, water, wastewater, and alcohol. The 316 stainless steel construction provides material compatibility with the documented media, while the IP65 enclosure rating and an operating temperature range of −40 °C to +85 °C support installation in demanding tank and instrumentation systems.
Mounting is performed using an S5 flange with five asymmetrically positioned mounting holes. The flange has an outer diameter of 69 mm, a bolt hole circle of 54 ±0.25 mm, and five 5.5 mm holes for M5 screws. The sensor tube has a diameter of 12.7 mm, the flange is 3 mm thick, and the associated NBR gasket seals the connection to the tank.
The nominal sensor length is 650 mm with a documented tolerance of ±2 mm. The electrical cable measures 460 ±20 mm and has two conductors: the blue conductor is connected to the instrument's S-terminal, while the black conductor is connected to common negative or ground. The nominal electrical power is 125 mW, and the maximum operating current is 300 mA.
The sensor is compatible with level instruments that support a signal range of 240–33 Ω, including relevant instruments from Teleflex, Aqua Meter, Vetus, S. Giorgio Sein/Veglia, Beede, Medallion, Datcom, and Wena/Wema. The documented 12 V level instrument with item no. 27.160.00 can also be used. Instruments designed for 0–190 Ω or 10–180 Ω must not be assumed to be compatible.
The product series is covered by EMC Directive 2014/30/EU and the standards EN 61326-1:2013, EN 61000-6:2007, and EN 61000-6:2007/A1:2011/AC:2012. Check the tank's internal depth, the S5 flange's hole pattern, and the instrument's resistance range before installation.
Key featuresVertical float-based level measurement
Nominal length: 65 cm
Resistance signal: 240–33 Ω
Compatible with 12 V and 24 V installations
316 stainless steel
S5 flange with five mounting holes
For petrol, diesel, water, wastewater, and alcohol
Enclosure rating: IP65
Operating temperature: −40 °C to +85 °C
Cable length: 460 ±20 mm