This vertical tank level sensor with S5 5-hole flange, 0–190 Ω is a 300 mm long, tubular resistance sender for measuring liquid levels in fuel and water tanks. A float moves axially along the sensor tube and changes the output resistance in accordance with the liquid level. The sensor can be used for gasoline, diesel, water, wastewater, and alcohol.
The sensor is compatible with 12/24 V systems and has an output range of 0–190 Ω. The rated power is 125 mW and the maximum operating current is 300 mA. The permitted deviation of the resistance output is ±(1 Ω + R × 1.5 %). Connection is made via two wires, and the installed cable has a length of 460 ±20 mm.
The construction is made of AISI 316 stainless steel and is supplied with an NBR gasket. The sensor has an IP65 protection rating and a documented operating temperature range from −40 °C to +85 °C. The nominal sensor length is 300 mm with a tolerance of ±2 mm, while the sensor tube has a diameter of Ø12.7 mm.
The S5 flange has an outside diameter of Ø69 mm, a thickness of 3 mm, and five mounting holes of Ø5.5 mm positioned on a bolt circle of Ø54 ±0.25 mm. For installation in a tank without an existing flange, a center hole of Ø40 mm and five screw holes of Ø4.0–4.2 mm are used. The sensor is top-mounted with the gasket correctly oriented, and the screws are tightened in a star pattern.
The resistance signal is compatible with suitable level instruments from Yazaki with 3-wire connection, Faria Europa, VDO, Uflex, and Guardian. The instrument must be designed for the European 0–190 Ω range, which may also appear under the older designation 10–180 Ω. The variant-specific calibration runs from 0 Ω at a float position of 45 mm to approximately 191 Ω at more than 263 mm, measured downwards from the top of the sensor.
The sensor family meets the EMC requirements of Directive 2014/30/EU as well as the RoHS requirements of Directive (EU) 2015/863. Associated standards include EN 61326-1:2013, EN 61000-6:2007, and EN 61000-6:2007/A1:2011/AC:2012.
Key featuresVertical tank level sensor with axially moving float
Output signal: 0–190 Ω
For 12/24 V systems
Sensor length: 300 ±2 mm
AISI 316 stainless steel with NBR gasket
Top-mounting with S5 5-hole flange
For fuel, water, wastewater, and alcohol
IP65 and operating temperature from −40 °C to +85 °C
Cable length: 460 ±20 mm